Wednesday, August 10, 2016Description :
Since September 2015, the European ERP Directive has been advocating
Optimum performance for heating generators, including
Labeling, as is already the case for household appliances.
The French climate engineering sector notes that 66% of sales
2015 of the installed boilers concerned so-called condensing generators
(Gas or oil); A technology for achieving overall yields
Much higher than conventional boilers (low temperature), which
Will become a true reference in the future, as is already the case in
United Kingdom or the Netherlands where it constitutes 100% of the new
Facilities ...
Hyper economical to use, condensing generators
Nevertheless produce acid condensates which must be neutralized before
Discharge to sewers. Condensates are particularly harmful to
The environment, pose a threat to the functioning of the
Biological purification and septic tanks, but also damage to
Infrastructure of the drainage system ...
It should also be noted that condensates eventually degrade
Evacuations and cause piping
Evacuation of metal, thus weakening the foundation design ...
As an example, an average domestic condensing boiler
Can discharge up to 800 liters of condensate per year, with an average pH of 4/5
Gas boilers and 3/4 for oil-fired boilers, thus contributing to
Million liters of acid discharges daily spilled across the country.
Although French legislation has not yet legislated on the treatment of
Condensates of installations of <70 kW (one power
Residential), one understands the imperative need to treat them. For the
This is only a voluntary eco-citizen
Consumer, but Sentinel confirms that this is a genuine
Growth for the business of professional installers,
The installation itself or the change of the neutralization refill
During the annual visit ...

An ingenious mechanism for the total elimination of
Acid releases

Installed on the condensate drain pipe of the
Boiler with an inclination allowing a natural flow, the Condensafe +
Contains a refill composed of mineral granules. Equipped with a quantity
Of these mineral beads compared with the competing bids (approx.
100 grams more), this mechanism has a neutralizing power
Optimum on condensates. Its composition eliminates the risk of blockage:
Granules do not agglomerate and do not reduce the overall effectiveness of
The equipment, for a neutralizing effect which retains the same intensity.
A proven quality
Independent firm Enertek International has
Made a complete technical evaluation of the Condensafe +, as well as a battery
Of tests to conclude that the Condensafe +:

- resists a pressure of 1.5 bar without any leakage,
Beyond normal operating pressure;

- removes more than 90% of the condensate acidity;

- is able to withstand flows much higher than those
Required by the boiler including when the body of the neutralizer has been
Totally blocked (test carried out with sand and displaying a flow rate of 6.25
Liters / minute).
Easy to install
Suitable for all types of domestic boilers
Condensation oil and gas up to 70 kW, as well as to different modes of discharges
(Constant or periodic net), the Condensafe + advocates a great facility
Of installation. Comes with refill and 32 fittings, it is totally
Ready-to-use! The unit does not
Easy and quick installation. It does not create any discomfort for the
Circulation of air and condensate in the evacuations. In addition, a
Bypass eliminates the risk of blockage of condensates and
Back to the boiler.
A SAV facilitated and generating business for the
professional

This innovative and intelligent design also
Suppliers and users easy maintenance. A flap strategically
Recovered debris discharged upstream. The low screw cap, located at
Level of the flap, facilitates access to debris for easy maintenance and
fast. The high screw cap provides easy access to refills and
A practical control point of the equipment. Used refills may
Be disposed of safely with household waste.
Annual replacement of the recharge is necessary
During the maintenance visit of the boiler and does not require any
Change the entire neutralizer. The installer must offer the
Annual replacement of the cartridge to guarantee true performance and
Genuine protection; This will also generate additional sales
Not negligible ...

Searches related toHeating, Air Conditioning